LOGO-NÚCLEO-A2

STACBOND A2 is a non-combustible composite panel composed of two aluminum sheets and a mineral core developed to meet the highest fire classification standards. Thanks to its exceptional mechanical properties: high rigidity, excellent flatness, impact resistance, durability and ease of maintenance together with a reaction to fire classification A2-s1, d0 (according to UNE EN 13501-1:2007), make it the ideal cladding solution for high-rise and high-occupancy buildings. It complies with the strictest fire classification requirements, among which the following stand out: 

  UNE EN 13501-1 – A2-s1, d0

  NFPA 285 – PASS

  ASTM E84 – CLASS A: SD: 10; FS: 0

  MSZ 14800-6:2020 – PASS 

 DIBt 75-1.10.3-809/1

Technical data

Technical details
Physical specification Unit Value Norm
Total thickness mm 4
External painted face thickness mm 0.50
Internal painted face thickness mm 0.50
Panel weight kg/m2 9.30 ± 0.50
Visible face aluminium alloy 5005 UNE EN 573-3
Hidden face aluminium alloy 3005 / 3105 UNE EN 573-3
A2 core specification Unit Value Norm
Density g/cm3 2.20 ± 0.15
Fire reaction A2 - S1, d0 UNE EN 13501-1:2007

Environmental certifications

Country Norm Organism LOGO-NÚCLEO-A2 LOGO-NÚCLEO-FR
INTERNATIONAL EPD
S-P-01289
Tecnalia R&I
Guipúzcoa
Certificado Certificado
EUROPE LEED
2014
USGBC Certificado Certificado

Fire certifications

LOGO-NÚCLEO-A2 LOGO-NÚCLEO-FR
Country Norm Classification Classification
UE EN 13501-1 A2-s1, d0 B-s1, d0
POLONIA PN-90/8-02867 NRO NRO
USA ASTM E84 CLASS A: SD: 10; FS: 0 CLASS A: SD: 5; FS: 0
USA NFPA 285 PASS PASS
CANADA CAN/ULC-S102-18 CLASS A: SD: 0 FS: 0
CANADA CAN/ULC-S134 PASS
HUNGARY MSZ 14800-6 PASS

Specifications of use


There may be limitations in the manufacture of STACBOND A2 panels with high gloss finishes. Please consult for compatible finishes.

Finishes

Transformation

Mounting Systems

STACBOND® composite panel

Coil coating